Acoustic resistance

Acoustic isolation

Acoustic resistance of materials is associated with the right of weight. The heavier the construction material, the better it insulates and dampens sound. In the case of walls made of AAC, it turns out that the porous structure of AAC gives this material a bonus of 2-3 decibels with respect to acoustic resistance, enhancing the acoustic resistance of building partitions compared to the materials of the same weight.

Walls of AAC were tested at the Acoustics Department of the Building Research Institute. On the basis of laboratory tests and obtained indicators of acoustic resistance adjusted by 2 dB, design values ​​of acoustic resistance indicators RA1R and RA2R have been specified.

THE ONDICAYOR OF ACOUSTIC RESISTANCE ASSESSMENT assessment RA1R i RA2R [DB] FOT WALLS MADE OF BLOCKS DEPENDING ON THE WALL DENSITY AND THICKNESS CLASS INN ACCORDANCE WITH EN 20140-3  

Density classThe value of single number ratios RA1R and RA2R [dB] for wall thickness without plaster [mm]
RA1R – for interior wallRA2R – for exterior wall
7510011515017520024030036542075100115150175200240300365420
350--37---45-----34---41-
400----38-41444647----35-38404244
5003135-39-42----3033-36-39----
600--37-43-464850---35-39-424547-

RA1R indicator refers to the internal partitions, since it is used to evaluate the partition’s resistance to a living noise, and the RA2R indicator refers to exterior partitions – it is used to evaluate the resistance of the partition to low-frequency (traffic) noise.